Calibration of Time-Skew Error in a M-Channel Time-Interleaved Analog-to-Digital Converters
Offset mismatch, gain mismatch, and time-skew error between time-interleaved channels limit the performance of time-interleaved analog-to-digital converters (TIADC). This paper focused on the time-skew error. A new technique for calibrating time-skew error in M-channels TIADC is developed, and simulation results are also presented.
Calibration time-skew error time-interleaved analog-to-digital converters nonuniform sampling
Lee Yu-Sheng Qi An
The Key Laboratory of Physical Electronics of Anhui Province,University of Science and Technology of China,Hefei,230026,China
国际会议
西安
英文
2007-08-16(万方平台首次上网日期,不代表论文的发表时间)