Calibration of Time-Skew Error in a M-Channel Time-Interleaved Analog-to-Digital Converters

Offset mismatch, gain mismatch, and time-skew error between time-interleaved channels limit the performance of time-interleaved analog-to-digital converters (TIADC). This paper focused on the time-skew error. A new technique for calibrating time-skew error in M-channels TIADC is developed, and simulation results are also presented.

Calibration time-skew error time-interleaved analog-to-digital converters nonuniform sampling

Lee Yu-Sheng Qi An

The Key Laboratory of Physical Electronics of Anhui Province,University of Science and Technology of China,Hefei,230026,China