会议专题

Error Analysis and Compensation of roll Measuring Device for Roll Grinder NC

There are many parameters that cause roll measurement error of roll grinder NC. The Effect factors of probe error in roll two-point measurement approach are analyzed, and the mathematic models and compensation methods of the probe static error and dynamic error are proposed in this paper. Based on the original control system and hardware of Roll Grinder, we designed a new type measuring device and error compensation software system. And the experiment shows that the probe compensation operation can greatly improve the measurement accuracy.

Roll Grinding NC Error analysis Measurement method Error compensation

Yan Liwen Wang Meiting Yu Tao

Mechanical Engineering Department of Changshu Institute of Technology,Jiangsu Province 215500 China; College of Mechatronics Engineering and Automation of Shanghai University,Shanghai 200072 China

国际会议

第八届国际电子测量与仪器学术会议(Proceedings of 2007 8th International Conference on Electronic Measurement & Instruments)

西安

英文

2007-08-16(万方平台首次上网日期,不代表论文的发表时间)