Improving current sharing of Paralleled UPS System
A load-sharing control scheme is studied for the paralleled uninterrupted power supplies (UPSs) in this paper. Integrated with the power control and the output filter current control, the proposed load-sharing control can improve the current-sharing quality of the parallel UPS system. In the experiments, two paralleled 30 KVA three-phase UPSs are used.
Yu Wei Zhou Chao Yang Yi Chen Dehong Xu
Zhejiang University P.R.China
国际会议
PCIM China 2007(International Conference Power Electronics)(2007年中国电力电子技术国际会议)
上海
英文
2007-03-21(万方平台首次上网日期,不代表论文的发表时间)