Design of a PMMW Imaging system

A compact passive mm-wave imager (PMMW) has been developed for imaging with 3mm Dicke-Radiometer and will be reported here. It uses a single-channel scanned super-heterodyne radiometer. To solve the contradiction of sensitivity and spatial resolution for the motive platform imaging, adjustable integrator was designed and wavelet-analysis was adopted to wipe off noise effectively. To test a close range and different plane for imaging, two set antenna was designed for imaging. The parameters of the radiometer are given below: the center frequency 91.5 GHz, the system band-width 4GHz, the sensitivity 0.5K, the linearity 0.9999.

LI Liang Chao YANG Jianyu Zheng Xin Fan Yong Zhang Rong Hong

School of Electronic Engineering, University of Electronic Science and Technology Chengdu, China, 610054