Numerical simulation on the feasibility of the wading pool heat pump in residential buildings
In the paper, based on lumped -heat -capacity method and finite difference method, through the medium of programming count, thermal storage of the wading pool has unsteady state heat transferring count. In the intermittent and continuous run of air-conditioning, the paper analyses how the temperature of the pool change. And according to the run result of the program, it also presents the influence of several parameters on heat transfer between the wading pool and the soil. The results prove the wading pool heat pump have a good capacity of thermal storage. And it can run chronically, safely and effectively for the residential buildings. It is feasible that it can be primary cold/heat source for air conditioning in the residential buildings, especially in the villas.
wading pool heat pump lumped- heat- capacity method finite difference method residential buildings
DAI Xiao-li ZHU Kong-min SONG Si-hai
School of Energy and Power Engineering, Jiangsu University, Zhenjiang, Jiangsu, 212013, China Zhuhai Architecture Design Insititute.Zhuhai Guangdong, China Nanjing Hydraulic Architecture Engineering Company, Nanjing, Jiangsu, 210036, China
国际会议
哈尔滨
英文
406-408
2007-01-15(万方平台首次上网日期,不代表论文的发表时间)