A THEORETICAL STUDY ON THERMO-ENVIRONMENTAL INDOOR HEATING BASED ON SOLAR BUILDING INTEGRATION
The optimal tilted angles of cylindrical absorber evacuated tube solar collector used for different months and for entire year in Kunming have been calculated, and its optimal tilted angle for entire year is 23.5o. The area compensation of collectors at different azimuth and tilted angles have been carried out on conditions that the useful energy output of the collector unit at different angles equals to that of the one facing due south with the optimal tilt angle. The indoor temperature of the room with large area south single-glass window has been simulated and analyzed. Solar low-temperature heat-water floor radiant heating system has been designed and modeled, the synthetical influences of solar radiation penetrating south window and solar low-temperature heat-water floor radiant heating on the indoor temperature of the room have been researched. All above mentioned results will offer some valuable reference data to the designs and applications of solar energy integrated with the building.
Li Ming Wei Shengxian Wang Liuling
Solar Energy Research Institute, Yunnan Normal University Kunming 650092, China Department of Physics, Qujing Normal University, Qujing 655011, China. School of Physics and Electronic Information Yunnan Normal University Kunming 650092, China
国际会议
2007世界太阳能大会(Proceedings of ISES Solar World Congress 2007)
北京
英文
2007-09-18(万方平台首次上网日期,不代表论文的发表时间)