SOLAR COMBISYSTEMS WITH BUILDING-INTEGRATED EVACUATED FLAT-PLATE COLLECTORS
Solar combisystems with building-integrated atmospheric and subatmospheric (evacuated) solar collectors have been investigated. Standard efficiency curves for investigated solar collectors were derived from software tool KOLEKTOR 2.2 for flat-plate collector heat transfer calculations. Combisystems performance characteristics (solar fraction, specific stagnation time) and influence on building indoor environment (winter heat gains, summer heat loads) are analysed through TRNSYS simulations. Three types of solar collectors (atmospheric, evacuated to 1 kPa, vacuum with 0.1 Pa) and three types of collector-building configuration (separate installation, roof integration, facade integration) were compared.
Juliane Metzger Tomas Matuska Borivoj Sourek
Dept.of Environmental Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague Technicka 4 Prague 6, Czech Republic
国际会议
2007世界太阳能大会(Proceedings of ISES Solar World Congress 2007)
北京
英文
2007-09-18(万方平台首次上网日期,不代表论文的发表时间)