THERMAL AND ELECTRICAL PERFORMANCE OF AN AIR TYPE PV/T SYSTEM
The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV systems electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. This paper describes the thermal and electrical performance of a roof-integrated PV/T system with forced ventilation at the space between the PV modules and the roof envelope through an experiment.
Jin-Hee Kim Hyun-Ju Lee Eon-Won Yang Jun-Tae Kim
Kongju National University, Graduate School Department of Architectural Engineering Shinwangdong 182 Kongju National University, Department of Architectural Engineering Shinwangdong 182, Kongju city, C
国际会议
2007世界太阳能大会(Proceedings of ISES Solar World Congress 2007)
北京
英文
2007-09-18(万方平台首次上网日期,不代表论文的发表时间)