TWENTY-EIGHT YEAR CONTINUED PERFORMANCE OF THERMAL AIR COLLECTOR SYSTEM
This report covers development, testing and continuous successful 28 year operation of an air solar collector heating system developed for the US Department of Agriculture servicing rural housing 1975-1979. The 44.13 SQ Meter (475SF) surface area test collector has operated continuously without physical deterioration at a New York USA test facility since 1980. The collector consists of a series of parallel horizontal thin, steel ducts with thermal transfer mechanism forming the absorber plate. The steel absorber has aluminum-zinc-silicon coating overlayed with select black paint baked in under a factory coil coating process. Glazing is of two sheets of 0.03% iron oxide rolled tempered glass 3.2mm (1/8) thick. Insulation is of polyisocyancurate. The components are site assembled.
Douglas A.Wilke
38 Roosevelt Avenue Glen Head, New York 11545 USA