EXPERIMENTAL STUDY ON THE SOLAR-WALL-AIR-COLLECTOR AND SOLAR HOUSE

A solar-wall-air-collector used for heating buildings is introduced. In the paper, using natural flow and forced flow transfer for collector are all investigated. In the experiments, the collectors heat efficiency is abort 30.4% when heated air is natural convection, and is about 60% when the collector is placed vertical with ventilating device. Using two collectors with ventilating device to the solar house which heat load is 82.6W/m2, the temperature of the indoors is abort 15.7℃, in authors opinion, it is feasible to use in the schools or factories heating where have enough sunlight.

Liping Zhang Hongju Ma Haibo Liu Jianli Zu

Technical Department of Himin Solar Energy Group Co.,Ltd, No.37, Hubinbei Road DezhouCity, Shandong Province, 253092,China

国际会议

2007世界太阳能大会(Proceedings of ISES Solar World Congress 2007)

北京

英文