A FORMULA OF THE WIDTH-THICKNESS RATIO OF THE PLATE OF STEEL OF SRC COLUMN
There is an ultimate value of the width-thickness ratio of the steel in the Steel Reinforced Concrete Composite Structure Specification in China. In the table 4.3.4 the width-thickness ratio of the web as for Q235 is less than 96. But there is no calculate theory in the specification. There is a complement note in the specification clause declaration that the ultimate value comes from the experience of Japan. So a practical formula fitted from 150 samples by ANSYS is given to check the precision of the ultimate value in the specification.
width-thickness ratio bonding slipping ultimate load contacting nonlinear
Haizhou Chen Shanjian Qilin Zhang
Tongji University, China Southeast University, China
国际会议
The 9th International Conference on Steel Space & Composite Structures(第九届国际钢材、空间结构、组合结构会议)
烟台·北京
英文
309-314
2007-10-10(万方平台首次上网日期,不代表论文的发表时间)