Survey on winter humid environment in Xian City
In terms of moving automobile investigating method, temperature and relative humidity data of 280 locations in Xian City were collected by automatic data recording device in daytime and nighttime on Feb. 7th 2006 and in nighttime on Feb. 20th 2006 respectively under clearness and less cloudy weather. The humidity ratio of each location was calculated according to data of temperature and relative humidity after correcting them to be synchronous. The results show that the humidity ratio in south suburb is higher than that in urban centre and north suburb in winter in Xian City. Urban dry island intensity is about 0.3 g/kg(dry air) in daytime and 0.4 -0.5 g/kg(dry air) in nighttime, influenced by urban heat island, the relative humidity increases from urban centre to suburbs gradually,the differences of relative humidity between urban centre and suburb are about 10%RH and 20%RH in daytime and nighttime, respectively.
humid condition relative humidity moving automobile investigating method urban dry island
LIU Yan-feng YANG Liu WANG Yi LIU Jia-ping
School of Enviromental and Municipal Engineering, Xian University of Architecture and Technology, Xian 710055, China
国际会议
重庆
英文
105-109
2006-04-04(万方平台首次上网日期,不代表论文的发表时间)