会议专题

CFD ANALYSIS OF CONDENSER IN A DOMESTIC AIR CONDITIONER

CFD simulation of a 1-row condenser in a domestic air conditioner is made. 2D models, with uniformly constant fin temperature overestimate significantly the heat transfer coefficient. 3D models, taking into account tube effects, conjugate heat transfer and conduction through the fin are in better agreement with the experimental results. A condenser experiment system is designed and built to validate the CFD result. Calculations are performed for different air frontal velocities and different condensation temperature. Even if an offset(less than 9%) of between CFD calculations and the experimental results, the trends are comparable and CFD study permits to reach local information, leading to better understanding of the physical phenomena involved in compact heat exchangers. The prediction outside the experiment range is discussed by performing “numerical experiment. It is found that there is optimum fin space when other structure parameters of the tube-fin condenser are given, and there is optimum tube space when other structure parameters of the tube-fin condenser are given.

Jinfeng Wang Leren Tao Yonghong Wang

University of Shanghai for Science and Technology, Number 516 Jungong Road,Shanghai, 200093, China Trane company in China, Raftle City,Shanghai, 200001,China

国际会议

The 22nd International Congress of Refrigeration(第22届国际制冷大会)

北京

英文

2007-08-21(万方平台首次上网日期,不代表论文的发表时间)