Study on Inner Flow Field Infection Caused by the Number of Impellers of Low-Ratio-Rev Open-Impeller Centrifugal Pump
According to the geometry of flow path and characteristic of flow field of low-ratio-rev open-impeller centrifugal pump impellers, S-A Turbulent flow model was adopted, and high quality of configurational sticking gridding was established. Combined with the Reynolds times averaging method and wall function, three-dimensional Turbulent flow calculation was done for inner flow field of impellers. According to the calculation results, the infection of flow velocity distribution, pressure distribution and pump performance of low-ratio-rev centrifugal pump caused by the number of impellers was analyzed and summarized, the flow law of Turbulent flow in impellers was developed, and theoretic foundation of optimization design for low-ratio-rev centrifugal pump was presented in this thesis.
Centrifugal pump Inner flow field Numerical value simulation Results analysis
Zhang Jianci Zhu Zuchao
Dep. of Mechanical & Electrical Control Engineering of Zhejiang University of Technology West Branch Zhejiang Provincial Key Lab of Modern Textile Machinery, Zhejiang Sci-Tech University, Hangzhou 3100
国际会议
北戴河
英文
254-258
2007-06-06(万方平台首次上网日期,不代表论文的发表时间)