The New Process of Measuring Method for Luminance Contrast in Bright Room Condition
A new measuring process for luminance contrast under bright-room condition is detailed. Luminance contrast is one of the most important parameters for the visual quality characterization of Flat Panel Displays ( FPDs) . Especially for mobile displays , it should be considered not only to determine the contrast in indoor condition under warm light illumination , but also the contrast in outdoor condition under daylight illumination. Fluorescent lamp illumination measurement and sphereinside diffuse illumination measurement are introduced. And then, we present sphere-outside diffuse illumination measurement. Moreover, to remove the embarrassment of implementing CIE standard illuminants (A, D65) lighting, we put forward spectroradiometric method as a complement to perfect sphere-outside diffuse illumination measurement.
Luminance Contrast Bright-room Condition Spectroradiometric Method Contrast Ratio
Tongsheng Mou Jiangping Wang
State Key Lab of Modern Optical Instrumentation of Zhejiang University,Hangzhou 310027, China ZheJiang University SENSING Instruments Co., LTD,Hangzhou 310013, China
国际会议
上海
英文
268-272