会议专题

Uncertainties in the Led luminous flux measurement using integrating sphere

The uncertainties in the LED luminous flux measurement using integrating sphere method are analysed. The analysis is mainly focused on the uncertainties arising from the spatial responsivity nonuntformity of the integrating sphere. And a correction method for spatial responsivity nonuniformlty error is proposed. The uncertainties due to spectral mismatch and self-absorption are also discussed as well. The analysis is based on the method of GUM and Monte Carlo simulation. The analysis results can be used as a guide to the measurement practices for the luminous flux of LEDs using integrating sphere method.

LED luminous flux measurement uncertainty photometry

Pan Jiangen Shen Haiping Feng Huajun

EVERFINE PHOTO-E-INFO CO., LTD., China Zhejiang University, China

国际会议

26th Session of the CIE(国际照明委员会(CIE)第26届大会)

北京

英文

228-231

2007-07-04(万方平台首次上网日期,不代表论文的发表时间)