Validation of cie averaged led intensity measurement by comparing results of the photometric and spectroradiometric methods with different traceabilities
We compare two different methods for measuring the averaged LED intensity defined by CIE. One is the photometric method using a photometer, whose luminous responsivity is traceable to the detector-based candela scale of KRISS. The other is the spectroradiometric method using a spectroradiometer, which is calibrated with a spectral irradiance standard lamp supplied by NIST. From the agreement of the results between these two methods with different traceabilities, we validate our measurement capability for the CIE averaged LED intensity.
light-emitting diode averaged LED intensity photometer spectroradiometer
Yong-Wan Kim Seongchong Park Dong-Hoon Lee Seung-Nam Park
Division of Physical Metrology, Korea Research Institute of Standards and Science (KRISS), 1 Doryong-Dong, Yuseong-Gu, Daejeon, Rep. Korea
国际会议
26th Session of the CIE(国际照明委员会(CIE)第26届大会)
北京
英文
347-349
2007-07-04(万方平台首次上网日期,不代表论文的发表时间)