Study on Sensor Array Applied in Electromagnetic Tracking System

Electromagnetic trackers have many favorable characteristics but are notorious for their sensitivity to magnetic field distortion resulting from metal and electronic equipment environment. Tracking position accurately and precisely important in 3D Electromagnetic tracking system. so in past years, many work focus on the location of tracker calibration techniques.This paper presented a new tracking method using magnetoresistive sensors array to reduce location errors. With new structure of receiver, a new calibration method is established. According the distance error between two-parallel sensors, the actual location error is compensated. Bench-testing results show the resolution and accuracy evaluated.

Hao Wang Guotai Jiang

School of Life Science and Technology, Tongji University, Shanghai, China, 200092

国际会议

2007 IEEE/ICME International Conference on Complex Medical Engineering-CME2007(CME2007 第二届国际复合医学工程学术大会)

北京

英文

190-193