会议专题

Experimental Flow Studies on Carotid Artery Models with and without Stents

Stents in carotid arteries are used for patients with high risk factors. This procedure however comes sometimes clotting and also restenosis. The flow disturbance influences the clotting and restenosis dramatically. Therefore we studied the flow behaviour of two covered stent, which were positioned differently and compared the velocity distribution with the measurements in an healthy carotid artery model. The covered stents were positioned from the common caroted artery(CCA) in to the internal carotid artery(ICA). The flowrate change and the velocity distribution was measured with a laser- Doppler Anemometer. The stents influenced the flow behaviour significantly. The flow rate ratio changed from 70:30 to 80:20 for the better positioned model.

Laser Doppler Anemometry Velocity Measurements Stent Carotid Artery Elastic Model

Peng, Y. H. Liepsch, D. Schmid, Th. Klügel, G. Sakurei, A. Wang X. B.

Department of Biomedical Engineering, Beijing Institute of Technology, Beijing, 100081 China University of Applied Sciences, Munich, Germany Kansai University Suita, Osaka, Japan Beijing Tongren Hospital, Capital University of Medical Sciences ,Beijing 100730,China

国际会议

2007 IEEE/ICME International Conference on Complex Medical Engineering-CME2007(CME2007 第二届国际复合医学工程学术大会)

北京

英文

220-226

2007-05-23(万方平台首次上网日期,不代表论文的发表时间)