The Implementation of PRP/HSR based on 3-in-1 networkin Smart Substation
This paper analyzes the application of 3-in-1 network,which includes MMS network of station level,GOOSE network and SV network of process level in smart substation.Being aimed at the problems of real-time performance and reliability of network communication,this paper proposes an implementation scheme of 3-in-1 network for smart substation based on IEC 62439-3(PRP/HSR)protocol and discusses it in detail.In this paper,research and development of the key equipments are introduced and relevant experiment verification and test results are summarized.Finally,this paper discusses the application design and analysis of distributed bus differential protection based on HSR.
3-in-1 Network Smart Substation PRP/HSR Dual-network Redundancy Seamless Recovery
ZHOU Hualiang ZHENG Yuping YANG Zhihong Jiang Lei WAN Luofei MAO Yishi
NARI Group Corporation(State Grid Electric Power Research Institute),Nanjing211106,China;NARI Techno NARI Group Corporation(State Grid Electric Power Research Institute),Nanjing211106,China;State Key L NARI Group Corporation(State Grid Electric Power Research Institute),Nanjing211106,China;NARI Techno
国内会议
南京
英文
239-249
2017-08-12(万方平台首次上网日期,不代表论文的发表时间)