The appropriate supply water temperatu re for capillary radiant floor heating system in Chongqing winter
In order to get the appropriate water supply temperature of capillary radiation floor heating system in the winter in Chongqing,In this paper,the experimental study and computational fluid dynamics(CFD)method are used to study the suitable water supply temperature on the radiation cooling and heating experiment platform of Chongqing University.The experimental study on the suitable water supply temperature of the capillary heating system in Chongqing is discussed.In this experiment,the floor temperature and air temperature at different water supply temperatures were obtained.The temperature distribution of the indoor temperature was calculated by cfd.The experimental study has a guiding significance for the selection of the water supply temperature of the winter capillary radiant floor heating system in Chongqing.
capillary radiation system thermal environment heating hot-humid region
Tianyue Hu Hong Liu Yuxin Wu
Joint International Research Laboratory of Green Buildings and Built Environments(Ministry of Education),Chongqing University,Chongqing 400045,China;National Centre for International Research of Low-carbon and Green Buildings(Ministry of Science and Technology),Chongqing University,Chongqing 400045,China
国内会议
中国环境科学学会室内环境与健康分会第八届学术年会( IEHB 2017)
重庆
英文
1-7
2017-11-04(万方平台首次上网日期,不代表论文的发表时间)