会议专题

Study on the Application of Negative Ionizers for Removing Airborne Pathogens in Ventilated Rooms

  The airborne contaminants cannot be eliminated by mechanical ventilation or filtering,but they can invade again into other air-conditioning zones via returning or recirculated air.This paper mainly focuses on the utilization of ionizers in ductwork for removing particulates from indoors.The selected room was separated into two rooms but served by one ductwork.The ionizers were installed at different locations inside the ductwork.A pollutant source was released in one of the two rooms.The governing transportation equations for negative ions and pollutant(Escherichia coli)were modeled and numerically solved by implementing them into FLUENT as user scalars.The simulation results show the contaminant was removed and the application of ionizer can effectively block the pollutant entering into other clean rooms.By comparing 4 ionizer installation scenarios,it is concluded that both the return and supply inlet should be mounted an ionizer to get the highest removal efficiency.

Negative ionizer Airborne removal Ventilated room Numerical simulation

Pei Zhou Xiaoping Liu Xiangxiang Lv

School of Civil Engineering,Hefei University of Technology,Hefei,Anhui,China;Department of Architect School of Civil Engineering,Hefei University of Technology,Hefei,Anhui,China

国内会议

中国环境科学学会室内环境与健康分会第八届学术年会( IEHB 2017)

重庆

英文

1-7