Development and Application of Neutron Computed Tomography at CARR
Neutron imaging (NI) has unique feature compared with X-ray imaging for the difference of the transmission characteristics through matters.The sensitivity to light elements, especially hydrogen,and the large penetration length through metals give it special advantages.NI has become a particularly useful universal technique for scientific and applied studies in various research disciplines.This article reviews the recent development of neutron imaging at China Advanced Research Reactor (CARR), including the instrumentations for indirect and real-time imaging and their application for non-destructive testing of nuclear fuel rod, two-phase flow, fuel cell, rock and concrete, etc.
Neutron Imaging Computed Tomography China Advanced Research Reactor
Songbai Han Linfeng He Guohai Wei Meimei Wu Yu Wang Yuqing Li Hongli Wang Yuntao Liu Dongfeng Chen
Neutron Scattering Laboratory, Department of Nuclear Physics,China Institute of Atomic Energy, Beijing 102413, China
国内会议
成都
英文
97-105
2016-09-01(万方平台首次上网日期,不代表论文的发表时间)