会议专题

CFD ANALYSIS AND EXPERIMENT STUDY OF THE ROTARY TWOSTAGE INVERTER COMPRESSOR WITH VAPOR INJECTION

  The offset angle of the upper and lower part of the crankshaft will affect the resistance of discharge of low pressure stage cylinder and suction of high pressure stage cylinder in the rotary two-stage inverter compressor with vapor injection,and then affect the performance of compressor.This paper presents the performance of the rotary two-stage inverter compressor in different bias angle of the crankshaft,which calculated by CFD soft and compared with the experimental results.Under the operation of close vapor injection and open vapor injection,the performance of compressor can be improved by optimize the bias angle of crankshaft.

Liying Deng Shebing Liang Jia Xu Yusheng Hu

Compressor and Motor Institute of Gree Electric Appliances,Zhuhai519070,China

国内会议

2016国际制冷空调技术交流会

珠海

英文

148-152

2016-11-01(万方平台首次上网日期,不代表论文的发表时间)