会议专题

Development and Validation of 50th Chinese Driver”s Shoulder Finite Element Model

  In order to study the shoulder injury mechanisms and injury process,a finite element model of drivers”shoulder is modeled with anatomical structureslikehumerus,clavicle,scapula,jointsand ligaments.The model accurately reflects the shoulder of a Chinese 50th percent human body both in size and geometric features to improve the precision of the simulation.Quasi-static and dynamic three point bending simulation tests are carried out for clavicle and humerus according to thepost-mortem human subjects in literature.The simulation results are in good agreement with the experimental results.The shoulder model is coupled with thorax model to simulate the side impact,and the simulation result accurately predicts the fracture of clavicle.

automobile collision biomechanics model shoulder injury side impact

Liu Chaoyang Chen Jiqing Lan Fengchong Huang Wei

School of Mechanical &Automotive Engineering,South China University of Technology;Guangdong Provincial Key Laboratory of Automotive Engineering

国内会议

2016中国汽车工程学会年会

上海

英文

620-626

2016-10-26(万方平台首次上网日期,不代表论文的发表时间)