Experimental study of CRIO data acquisition device based on IEEE1588 time synchronization protocol
CompactRIO (CRIO) can be based to achieve time synchronization between multi systems on the based of IEEE 1588 synchronization protocol.This paper introduced the hardware composition, software design and synchronization test results of a remote distributed data acquisition system of CRIO.The test results show that the synchronization precision of the distributed system based on CRIO can reach sub millisecond level in short-term, and ms level in a long-term test.
CRIO time synchronization IEEE 1588 synchronous precision
Jinyu Wang Binxin Hu Guangdong Song Tongyu Liu
Key Laboratory of Optical Fiber Sensing Technology of Shandong Province, Jinan, 250014,China;Laser I Key Laboratory of Optical Fiber Sensing Technology of Shandong Province, Jinan, 250014,China;Shandon
国内会议
光纤和光电子传感器及其安全应用国际会议(OFSIS2015)
济南
英文
426-429
2015-01-20(万方平台首次上网日期,不代表论文的发表时间)