Junction temperature measurement to optimize thermal design of LED arrays

  The drive to increased electrical currents input to achieve high lumen output for High Brightness Light Emitting Diode (HB LED) has led to a series of thermal problems.Hence,thermal management is a key design parameter as the temperature directly affects the maximum light output,quality,reliability and life time.For LED arrays,the arrangement will affect the thermal performance.In the design,junction temperature is very important to detect.However,because direct junction temperature determination is hard to detect due to the encapsulation,indirect methods are more preferred.Using the diode forward-voltage method is the most accurate one.Therefore,we used the diode forward-voltage method to optimize thermal design of LED arrays in this work.

Huaiyu Ye Hongyu Tang Stanley Leung Cheng Qian Xuejun Fan Guoqi Zhang

Electronic Components,Technology and Materials,Delft University of Technology,Delft 2628 CD,The Neth Changzhou Institute of Technology Research for Solid State Lighting,Changzhou,213161,China State Key Laboratory of Solid State Lighting,Institute of Semiconductors,Chinese Academy of Sciences Department of Mechanical Engineering,Lamar University,Beaumont,Texas 77710,USA;State Key Laboratory Electronic Components,Technology and Materials,Delft University of Technology,Delft 2628 CD,The Neth