Research of Scale Problem in The Evaporation Cooler Based on Gas Flow Simulation in Dry Dedusting System
With energy saving and consumption reduction being required in iron and steel industry, the study of dry dedusting system of converter gas has been taken into account.Based on CFD simulation of flue gas,scaling problem appearing in evaporation cooler operation is analyzed.Result shows that scale is just related to stability of flue gas flow instead of velocity or temperature, and it could be efficiently abated with additional deflector.This research establishes a certain foundation to further optimization of evaporation cooler operation.
scale CFD simulation flow converter gas
Guang JIN Xingwang SONG
School of Environment and Energy, Inner Mongolia University of Science and Technology, Baotou, China
国内会议
北京
英文
129-131
2010-12-18(万方平台首次上网日期,不代表论文的发表时间)