Effect of bias magnetic field and electrical resistance load on the magnetoelectric properties of Terfenol-D/PMN-PT/Terfenol-D laminate composites
Based on the equivalent circuit method, the effect of bias magnetic field and electrical resistance load on the magnetoelectric (ME) properties of Terfenol-D/PMN-PT/Terfenol-D laminate composites has been theoretically investigated.The calculated change of the ME field coefficient with bias magnetic field and electrical resistant load shows a good agreement with the experimental data.Using this model, we theoretically analyze the variation of the ME coefficient with frequency under electrical resistant load and open-circuit condition, and find that the ME coefficient increase with frequency at a low frequency range (1-20 kHz) and sharply increases at the resonant frequency.Furthermore, this paper calculates and analyzes the influence of the thickness of the magnetostrictive layer and the length of laminate composites on the ME coefficient and resonant frequency of laminate composites.This research can provide a theoretical basis for the design of ME devices and their signal-processing and electronic circuits.
magnetoelectric composite magnetoelectric effect bias magnetic field effect electrical resistance load effect
Guo-Liang Yu Huai-Wu Zhang Yuan-Xun Li Jie Li
State Key Lab of Electronic Thin Films and Integrated Devices School of Micro-Electronics and Solid-Electronics,University of Electronic Science and Technology of China,Chengdu 610054,People,s Republic of China
国内会议
成都
英文
219-231
2013-11-15(万方平台首次上网日期,不代表论文的发表时间)