Study on Feasibility of Automatic Sprinkler System Applied in Underground Tunnel
Realizing the characteristics of underground fire and the actuality of fire protection facilities,and putting forwards the advice that we should set automatic sprinkler systems in underground tunnels.In this paper,the smoke development and the temperature distribution was simulated usingfield model (FDS).And the comparisons between the two cases were made.From the results we can see that setting automatic sprinkler systems in underground tunnels has both advantages and disadvantages.But considering synthetically it is feasible.
Underground Tunnel Fire FDS Automatic Sprinkler Systems Feasibility
DENG Yan-li ZHU Shu-min
School of Environment and Civil Engineering,North China Institute of Water Conservancy and Hydroelectric Power,Zhengzhou 450008,China
国内会议
沈阳
英文
85-91