会议专题

Study on Feasibility of Automatic Sprinkler System Applied in Underground Tunnel

  Realizing the characteristics of underground fire and the actuality of fire protection facilities,and putting forwards the advice that we should set automatic sprinkler systems in underground tunnels.In this paper,the smoke development and the temperature distribution was simulated usingfield model (FDS).And the comparisons between the two cases were made.From the results we can see that setting automatic sprinkler systems in underground tunnels has both advantages and disadvantages.But considering synthetically it is feasible.

Underground Tunnel Fire FDS Automatic Sprinkler Systems Feasibility

DENG Yan-li ZHU Shu-min

School of Environment and Civil Engineering,North China Institute of Water Conservancy and Hydroelectric Power,Zhengzhou 450008,China

国内会议

2012(沈阳)国际安全科学与技术学术研讨会

沈阳