The numerical simulation Study of Civil residence natural gas explosion and its destructive
The evolvement and the building breakage of a residential natural gas leakage explosion accident happened in Beijing was simulated as the study target.The simulation model of the explosion accident spot was set up by AutoReaGas,and 99 measurement points were distributed at the comers of room in the model.The evolvement and building breakage of explosion accident under 8 kinds of boundary (CASE1-CASE8) were analyzed.The changes over time of overpressure at each measurement points and the building breakage when the accident occurred were gained,and the simulation results show that the building breakage caused by the natural gas explosion in CASE1 and CASE5 are the most similar conditions to the accident spot,and the pure natural gas leakage capacity of the explosion accident is between 6.48 m3-19.65 m3.
natural gas explosion breakage numerical simulation leakage
LIU Mu PEI Yu-qi QI Zhi
Research Department of Emergency Technology and HSE Management System,CNPC Research Institute of Saf School of Chemical Engineering,China University of Petroleum,Beijing 102249,China
国内会议
沈阳
英文
530-535
2012-11-11(万方平台首次上网日期,不代表论文的发表时间)