会议专题

The Performance of Different Anti-Sealants on Silica-Scaling in Reverse Osmosis Plants

The effectiveness of anti-sealants for calcium carbonate and calcium sulphate is often determined in laboratory tests like the NACE Standard Test Method 03-74. Due (o the different chemical scaling mechanisms of the calcium hardness and of silica these test methods are not found reliable to simulate silica scaling. To investigate the performance of different anti-sealants for silica at a reverse osmosis plant, a new membrane-based test method was developed and applied.Figure 1 and 2 show the typical curve obtained for the permeance versus time. Figure 1 gives an example of the results obtained without using an anti-sealant, while Figure 2 shows an example where an anti-sealant has been applied.

Rainer Haug Luna Shi Wolfgang Hater Christian zum Kolk G Braun

BK Giulini Performance Products (Jiangyin) Co. Ltd , 58 Dongsheng Road, Jiangyin, Jiangsu, China BKG Water Solutions, Niederhcider StraBe 22, Diisscldnrf, Germany Cologne University of Applied Sciences, Bctzdorfer StraBe 2, Cologne, Germany

国内会议

2012青岛国际脱盐大会

青岛

英文

192-200

2012-06-26(万方平台首次上网日期,不代表论文的发表时间)