Solvent Extraction of Phenol with Cumene from Wastewater
In this paper, the extraction of phenol from wastewater using cumene as an extractant is investigated. H2SO4 and HC1 are used for the pH adjustment of the wastewater. The effects of extraction temperature, pH value, initial concentration and phase ratio on the extraction performance are studied. The results show that the distribution coefficient D increases with the increase of extraction temperature (from 25℃ to 55℃) and the decrease of pH value of the aqueous phase (from 13.0 to 0.0). The type of the acids and the initial concentration of phenol show a weak effect on the distribution coefficient. The stripping of loaded organic and the reuse of extractant are also discussed.
Phenol Solvent extraction Cumene
Junteng Liu Jing Xie Zhongqi Ren Weidong Zhang
State Key Laboratory of Chemical Resource Engineering, Beijing Key Laboratory of Membrane Science and Technology, Beijing University of Chemical Technology, P.O. Box 1#, NO. 15, N. 3rd Ring Rd East, Beijing 100029, People”s Republic of China
国内会议
青岛
英文
400-407