Study on Design Calculation of Heat Exchange for Ground-Source Heat Pump Buried Pipes
Temperature field for some depth under the ground was studied to the geological tectonic features of Wuhan.We studied several problems for designing the calculation of heat exchange of ground buried pipes.Engineering design for heat exchange of ground buried pipes and an engineering calculation software was acquired by using VB macro function in Excel based on a simple calculation model.We applied the calculation methods to an actual project.