会议专题

A Novel Micro-Pump Based on Osmosis Effect

This paper presents a novel micro-pump based on osmosis effect. It features simple structure, power- free, inexpensive, pulse-free and stable flow-rates during long working periods. The micro-pump is composed of two reserviors with a semipermeable membrane sandwiched in between. Factors affecting the flow rate of the micropump were primarily studied. With the 3.5cm<2> effective area of membrane, the flow-rates can be obtained from 40-530nL/min, with precisions of 6%-9%.

Micro-pump Osmosis effect Microfluidics

Chun-Guang Yang Zhang-Run Xu

Research Center for Analytical Sciences, Northeastern University, Shenyang, China

国际会议

The First Shenyang International Colloquium on Micrifluidics(首届沈阳国际微流控学术论坛)

沈阳

英文

92-93

2007-10-21(万方平台首次上网日期,不代表论文的发表时间)