Effect of heating-rate on failure temperature of pre-loaded brass H62
The response and failure of brass H62 specimens subjected to different levels of pre-loaded stresses and heating rates were investigated using a Gleeble-1500 thermal-mechanical material testing system. The metallographs of the tested material were also observed and analyzed. It is found that the increase of either pre-loaded stress or heating-rate decreases the failure temperature. Metallographic analysis shows that high heating-rate may cause stronger local thermal inconsistency (LTI) and remarkably increase the microdefects in the material, which may markedly degrade the macroscopic mechanical properties of the material.
brass H62 pre-loaded stress heating rate failure temperature local thermal inconsistency
CHEN Bin PENG Xiang-he FAN Jing-hong SUN Shi-tao
College of Resource and Environment Science,Chongqing University,Chongqing 400044,China
国际会议
2007年国际有色金属大会(International Conference of Nonfereous Materials 2007)(ICNFM)
长沙
英文
2007-11-28(万方平台首次上网日期,不代表论文的发表时间)