会议专题

Simulation Study of Cooling System Temperature Control Based on subsection control

  The primary purpose of temperature control for cooling system is to ensure the system discharge temperature within target range while preventing compressor outlet temperature from overheating.A two-level subsection control method is constructed to control the compressor outlet temperature and the system discharge temperature respectively.In addition,the target value of system discharge temperature is divided into three parts.In every part,the different target value of the compressor outlet temperature is given.The method not only makes sure that controlling the system discharge temperature is easier to be accomplished,but also reduces cost-compensation of system.The simulation result indicates that the system discharge temperature can be regulated smoothly to target value while controlling the compressor outlet temperature in design value.Meanwhile,the ram air valve(RAV)and the temperature control valve(TCV)are under normal condition during all processes.

Cooling system Temperature control Subsection control method

WANG Jiali Li Yanna

AVIC The First Aircraft Institute,1st RENMING Road,YanLiang county,XIAN,710089,China

国际会议

2014 Asia-Pacific International Symposium on Aerospace Technology(2014亚太航空航天技术学术会议)

上海

英文

1-8

2014-09-24(万方平台首次上网日期,不代表论文的发表时间)