Nonlinearity test and compensation of the passive AFOCTs scale factor
In order to compensate the nonlinear error of passive all-fiber optic current transformers (AFOCT) in the case of large current input,a new method based on the inverse function correction is presented.Taking the feature of the AFOCTs nonlinear response into account,a high-order signal is produced by an analog circuit,thus the scale factor of the AFOCT could be compensated quickly and accurately.Experimental test shows that when the phase difference between the two interference light paths is within the range of 0~20°,the output of the AFOCT could be compensated to maintain the GB/T 20840.8 0.2 accuracy class.
All-fiber optic current transformer nonlinear compensation analog multiplier
Xiao Yue-yu Yan Jin-kui Peng Lei
Key Laboratory of Specialty Fiber Optics and Optical Access Networks,Communication and Information Engineering,Shanghai University,Shanghai,P.R.China
国际会议
杭州
英文
523-526
2013-03-22(万方平台首次上网日期,不代表论文的发表时间)