Preliminary Analysis of Three ULOFAs Based on the Dual-Functional Lithium Lead Test Blanket Module Configuration in ITER
Based on the structural design of the Chinese ITER Dual Functional Lithium-Lead Test Blanket Module (DFLL-TBM), Three Unprotected Loss of Flow Accidents (ULOFAs) were investigated preliminarily, assuming that the whole nuclear heat in TBM was carried away by the flowing lithium-lead(LiPb). The results show that the temperature of the first wall (FW) increases rapidly and the maximum temperature appears at the lower part of FW. In the analysis of ULOFAs, the maximum temperature might exceed the melting point of structure material steel. This event must be avoided by the fusion power shutdown system that terminates plasma burn.
Weifeng Ni Suizheng Qiu Guanghui Su Wenxi Tian
School of Nuclear Science and Technology,Xi’an Jiaotong University, 710049, Xi’an, China School of Nuclear Science and Technology, Xi’an Jiaotong University, 710049, Xi’an, China
国际会议
18th International Conference on Nuclear Engineering(第18届国际核能工程大会 ICONE 18)
西安
英文
1-5
2010-05-17(万方平台首次上网日期,不代表论文的发表时间)