会议专题

Guaranteed Cost Control of the Water Level of Steam Generator Based on T-S Model

In the operation of nuclear steam generator, the reverse thermal-dynamic effects make steam generator water level process dynamics characteristic difficult to control. In order to improve the control effect, a guaranteed cost controller method based on T-S model for the water level control of a nuclear steam generator is proposed and investigated in this paper. The proposed controller guarantees both stability and a prescribed performance in the entire operating region in terms of linear matrix inequalities. The computer simulation shows that guaranteed cost controller can efficiently control the steam generator water level and achieve anticipative effects. It also demonstrates the effectiveness of the proposed controller in full operating range

Zhuo xiujuan Wang junling Feng zhangjun

College of Nuclear Science and Technology Harbin Engineering University,Harbin 150001,China

国际会议

The 2nd International Symposium on Systems and Control in Aeronautics and Astronautics(第二届航空航天系统与控制国际会议 ISSCAA 2008)

深圳

英文

1218-1222

2008-12-10(万方平台首次上网日期,不代表论文的发表时间)