Research on Double Parameters Discharge Gap Detection of Gap Voltage and Charging Current in Micro-EDM
In micro-EDM, for discharge energy and gap is very small, discharge state is much complex and changes very fast, traditional detection of average voltage cant judge discharge state in real time, so double parameters detection mode of gap voltage and charging current is designed. Based on characters of RC pulse discharge, three threshold voltage and current values of high, medium, low are devided according to charge constant. Gap voltage and charging current have fixed corresponding relationship, through this relationship, these two parameters can be combined as five different situations to determine three states of discharge machining, representing open-circuit, normal discharge and short-circuit. The combination of gap voltage and charging current can accurately judge gap state and further improve working efficiency in micro-EDM.
micro-EDM double papameters detection gap voltage charging current
Weiliang Zeng Ying Liu
Information Science Department, Harbin Normal University, Harbin, China College of Mechanical Engine Information Science Department, Harbin Normal University, Harbin, China
国际会议
2010 International Conference on Advanced Mechanical Engineering(2010年先进机械工程国际学术会议 AME 2010)
洛阳
英文
1211-1214
2010-09-04(万方平台首次上网日期,不代表论文的发表时间)