Optimal Transform of Multichannel Evoked Neural Signals Using a Video Compression Algorithm
One of the most important problems in the field of biomedical engineering is how to record a multichannel neural signal. This problem arises because recording produces a large amount of data that must be reduced to transfer it through wireless transmission, and data reduction must be made without compromising data quality. Video compression technology is very important in the field of signal processing, and there are many similarities between multichannel neural signals and video signals. Therefore, we use motion vectors (MVs) to reduce the redundancy between successive video frames and successive channels. We also test what transform for neural signal compression is best. Our novel signal compression method gives a signal-to-noise ratio (SNR) of 25 db and compresses data to 5% of the original signal.
biomedical signal processing video signal processing multielectrode signals
Chen Han Chung Liang-Gee Chen Yu-Chieh Kao Fu-Shan Jaw
DSP/IC Design Lab,Graduate Institute of Electronics Engineering,National Taiwan University Taipei Lab.of Electrophysiology,Institute of Biomedical Engineering,National Taiwan University Taipei
国际会议
北京
英文
1-4