会议专题

CFD-based Prediction on Thermal Pollution

This paper describes the work conducted to establish a thermal discharge model, by using the commercial computational fluid dynamics code FLUENT, in order to predict temperature distribution resulting from the thermal discharge into a lake. The results show that the thermal influence area is limited, although this thermal discharge system can pollute the water environment. After this thermal discharge is finished, the water temperature can recover in one hour.

Environmental protection water pollution control thermal pollution FLUENT

Junhua Wu Shijun You Haishan Li

School of Environment Science and Technology Tianjin University Tianjin 300072,China;College of Arch School of Environment Science and Technology Tianjin University Tianjin 300072,China College of Architecture Engineering and Mechanics Yanshan University Qinhuangdao 066004,China

国际会议

The 3rd International Conference on Bioinformatics and Biomedical Engineering(iCBBE 2009)(第三届生物信息与生物医学工程国际会议)

北京

英文

1-4