Seismic Isolation of the Roof over a Large Space Design of the Roof for Kyoto Aquarena
This indoor swimming pool has approximately 57-meter span at the maximum. The supporting structure is made of pre-cast pre-stressed concrete and the roof structure is composed of beam string structure (BSS). The base isolated system, the combination of laminated lubber and hysteric damper is placed on the connection between the supporting part of BSS and lower structure. Therefore the vibration response against seismic and wind force is reduced as well as the thrust caused by thermal stress and snow load is reduced evidently.
Seismic Isolation of Roof Pre-cast Pre-stressed Concrete Beam String Structure
KANEDA.Katsunori
Shibaura Institute of Technology. Structural Design Office Plus One Co.,Ltd. Japan
国际会议
14th World Conference on Earthquake Engineering(第十四届国际地震工程会议)
北京
英文
2008-10-12(万方平台首次上网日期,不代表论文的发表时间)