The parameters control for recirculation treatment of leachate
The three parameters, hydraulic loading rate 、organic loading rate and recirculation times have important influence on the efficiency of recirculation treatment. In the recirculation experiment, COD removal under different hydraulic loading rate 、organic loading rate and recirculation times were studied by the experimental devices built in landfill in Chongqing. The result indicated that the hydraulic loading rate is the major influence parameter for leachate was 70%~94%; organic loading rate has relatively minor influence on recirculation treatment; the apt recirculation times are 3 or 4 in a day ;C/N of recirculation leachate have important influence on NH3-N removal rate, but the effect of hydraulic loading rate and recirculation times on NH3-N removal rate arent obvious.
landfill leachate recirculation hydraulic loading rate
Jiang Bao-jun Yin Jun Zhang Li-guo Peng Ju-wei
School of Municipl and Environmental Engineeing, Harbin Institute of Technology,Harbin 150090,China; School of Municipl and Environmental Engineeing, Harbin Institute of Technology,Harbin 150090,China School of Municipl and Environmental Engineeing,Jilin Architectural and Civil Engineeing Institute,
国际会议
The 12th Asian Pacific Confederation of Chemical Engineering Congress(第十二届亚太化工联盟大会暨化工展览会)
大连
英文
2008-08-04(万方平台首次上网日期,不代表论文的发表时间)